Skip to main content

Table 3 Validation of the fully automated algorithm for CRBSI

From: Surveillance of catheter-associated bloodstream infections: development and validation of a fully automated algorithm

Cross tabulation of manual Surveillance and fully automated surveillance (validation sample (n = 853))

Manual surveillance

CRBSI

No CRBSI

Fully automated surveillance

CRBSI

5 (TP)

0 (FP)

No CRBSI

1 (FN)

847 (TN)

Performance of the fully automated algorithm

  Sensitivity

83.3% (95%CI: 43.7–96.9)

  Specificity

100% (95%CI: 99.5–100)

  Positive predictive value

100% (95%CI: 56.5–100)

  Negative predictive value

99.9% (95%CI: 99.2–100)

  1. CI Confidence interval, CRBSI Catheter related bloodstream infection, CLABSI Central line associated bloodstream infection, TP True positive, FP False positive, FN False negative, TN True negative