Skip to main content

Table 10 Comparison of the characteristics of aHP, H2O2 vapour, UV-C and PX-UV devices

From: The in situ efficacy of whole room disinfection devices: a literature review with practical recommendations for implementation

 

aHP

H2O2 vapour

UV-C

PX-UV

In vitro efficacy

Viruses: 2.5-log

Bacteria: >1 - >6-log

Spores 4.9-log

Fungi: –

Viruses: >4-log

Bacteria: >5 - >6-log

Spores > 6-log

Fungi: –

Viruses: –

Bacteria: >3.9 - >8-log

Spores 2.5-log

Fungi: >5-log

Viruses: –

Bacteria: >2.7 - >5-log

Spores 1.8-log

Fungi: 1-log

In situ efficacy

Reduction of environmental and clinical outcomes

Reduction of environmental and clinical outcomes

Reduction of environmental and clinical outcomes

Reduction of environmental and clinical outcomes

Homogeneity of disinfection

Not homogenous, unidirectional

Homogenous

Not homogenous under suboptimal circumstances

Not homogenous under suboptimal circumstances

Prior preparations in patient room

Cleaning, turning off smoke alarms

Cleaning, sealing doors/vents, turning off smoke alarms

Cleaning, removing curtains

Cleaning, removing curtains

Duration disinfection

2–3 h

1.5–2 h

Moving robot: 10–20 min

Stationary robot: 50 min

12–20 min

Required equipment

Device + disinfecting substance

Device + disinfecting substance

Device only

Device only

Compatibility materials

Not extensively investigated

Compatible with most materials

Might damage polymers

Not extensively investigated