Skip to main content

Table 9 An overview of the environmental and clinical outcomes of studies using PX-UV

From: The in situ efficacy of whole room disinfection devices: a literature review with practical recommendations for implementation

  

Environmental outcomes

Clinical outcomes

 

Micro-organism

Range of effect of all studies

Range of effect of stat. sign. findings

Number of studies

Range of effect of all studies

Range of effect of stat. sign. findings

Number of studies

Viruses

Norovirus

      

Bacteria

Acinetobacter

   

63% reduction

63% reduction

1 [89]

 

CPE

      
 

ESBL

      
 

MRSA

72.7– 90.9% reduction

72.7–90.9% reduction

5 [69, 97, 100,101,102]

20% increase to 37.9% reduction

26.7–37.9% reduction

4 [89, 92, 95, 107]

 

VRE

38–100% reduction

75–100% reduction

4 [69, 91, 103, 104]

18.9% increase to 52.7%

18.9–50% reduction

4 [90, 92, 93, 107]

Spores

C. difficile

59–100% reduction

63.6–94.8% reduction

3 [69, 105, 106]

18.6% increase to 53% reduction

17.2–53% reduction

8 [85, 90, 92,93,94, 96, 107, 108]

Yeast

C. auris

     Â