Introduction
Healthcare associated infections surveillance is a priority in intensive care units (ICUs).Since 2004, French national surveillance in adult ICUs (REA-RAISIN network) has targeted device-associated infections, for which control measures are essential.
Objectives
To present 2014 national results and highlight the impact of prevention programmes over the last six years.
Methods
Six months a year, ICUs collected data for each patient hospitalised more than 2 days. Surveillance focused on ventilation associated pneumonia (VAP), central venous catheter related infection or bacteraemia (CRI/CRB) and bloodstream infection (BSI) according to European protocol (ECDC). Analysis included patient’s characteristics, device exposures, ICU-acquired infections (microorganisms, antimicrobial resistance) and incidence ratios including ICU distributions and temporal trends (2009-2014). Multivariate analyses introducing the year of participation as a risk factor were performed for VAP and CRB.
Results
In 2014, 212 ICUs included 34,226 patients and 10.7% presented at least one infection. Overall incidence rates were calculated: 14.26 VAP/1,000 intubation-days, 3.53 BSI/1,000 ICU-days, 0.66 CRI and 0.51 CRB/1,000 catheter-days.
In comparison with 2009, patients were more predisposed to infections due to significant evolution of their characteristics (age, SAPSII, antibiotic treatment at admission, immunosuppression) meanwhile device exposure decreased. All incidence rates of device-associated infections decreased significantly: VAP (-6.2%), CRI (-40.5%) and CRB (-43.3%), meanwhile decrease is not significant for BSI (-1.1%). Multivariate analysis confirmed this reduction in 2014 for VAP (adjusted OR: 0.90; CI95: 0.84-0.97) and CRB (adjusted OR: 0.56; CI95: 0.44-0.71).
Conclusion
This surveillance network, including 50.4% of French ICU beds, represents a national reference and appears effective in describing and monitoring infectious risk in ICUs. The significant decrease in 2014 for VAP and CRB can be related to practice improvement and higher level of patient safety.
Disclosure of interest
None declared.
Author information
Authors and Affiliations
Consortia
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Savey, A., Machut, A., Lepape, A. et al. National results and 6 years trends of nosocomial infection surveillance in French intensive care units (REA-RAISIN network). Antimicrob Resist Infect Control 4 (Suppl 1), P236 (2015). https://doi.org/10.1186/2047-2994-4-S1-P236
Published:
DOI: https://doi.org/10.1186/2047-2994-4-S1-P236
Keywords
- Intensive Care Unit
- Central Venous Catheter
- Bloodstream Infection
- Ventilation Associate Pneumonia
- National Result