Microbiological assessment of the indoor air quality of a university health centre in Nigeria
Antimicrobial Resistance and Infection Control volume 4, Article number: P51 (2015)
Introduction
The air within the healthcare environment may serve as a reservoir for microorganisms thereby contributing to the rate of infection. Regular monitoring of the microbial burden is necessary to ascertain the microbiological quality of hospital environments.
Objectives
This study was conducted to evaluate the quality of the indoor air in a university health centre.
Methods
The air microflora was assessed using the settle plate method. Air samples were taken from the waiting room, consulting rooms, nurse station, male and female wards as well as the laboratory to detect bacterial and fungal flora. The antimicrobial activity of five commonly used disinfectants was tested on some of the isolated bacteria.
Results
Thirteen bacterial genera and two fungal genera were identified. The predominant bacteria were Klebsiella spp (15.7%), Bacillus spp (15.7%) and Streptococcus spp (10.5%). Among the less common bacterial isolates were Staphylococcus aureus and Clostridium spp. The fungal isolates include Aspergillus niger (50%) and Mucor spp (50%). The microbial burden was highest in the wards, followed by the consulting rooms and the waiting room. The antimicrobial activity the disinfectants varied with the concentrations tested. Klebsiella species were resistant to two of these disinfectants at all concentrations.
Conclusion
The findings of this study revealed the presence of possible pathogens. This emphasizes the importance of regular air surveillance and proper infection control practices in hospitals.
Disclosure of interest
None declared.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Ayepola, O., Egwari, L. & Olasehinde, G. Microbiological assessment of the indoor air quality of a university health centre in Nigeria. Antimicrob Resist Infect Control 4 (Suppl 1), P51 (2015). https://doi.org/10.1186/2047-2994-4-S1-P51
Published:
DOI: https://doi.org/10.1186/2047-2994-4-S1-P51
Keywords
- Infection Control Practice
- Klebsiella Species
- Fungal Flora
- Consult Room
- Predominant Bacterium