Using adenosine triphosphate bioluminescence level monitoring to identify bacterial reservoirs during two consecutive Enterococcus faecium and Staphylococcus capitis nosocomial infection outbreaks at a neonatal intensive care unit

Abstract

Introduction

This study aimed to assess the role of adenosine triphosphate (ATP) bioluminescence level monitoring for identifying reservoirs of the outbreak pathogen during two consecutive outbreaks caused by Enterococcus faecium and Staphylococcus capitis at a neonatal intensive care unit (NICU). The secondary aim was to evaluate the long-term sustainability of the infection control measures employed one year after the final intervention measures.

Methods

Two outbreaks occurred during a 53-day period in two disconnected subunits, A and B, that share the same attending physicians. ATP bioluminescence level monitoring, environmental cultures, and hand cultures from healthcare workers (HCW) in the NICU were performed. Pulsed-field gel electrophoresis (PFGE) typing was carried out to investigate the phylogenetic relatedness of the isolated strains.

Results

Four cases of E. faecium sepsis (patients A-8, A-7, A-9, B-8) and three cases of S. capitis sepsis (patients A-16, A-2, B-8) were diagnosed in six preterm infants over a span of 53 days. ATP levels remained high on keyboard 1 of the main station (2076 relative light unit [RLU]/100 cm2) and the keyboard of bed A-9 (4886 RLU/100 cm2). By guidance with the ATP results, environmental cultures showed that E. faecium isolated from the patients and from the main station’s keyboard 1 were genotypically indistinguishable. Two different S. capitis strains caused sepsis in three patients. A total 77.8% (n = 7/9) of S. capitis cultured from HCW's hands were genotypically indistinguishable to the strains isolated from A-2 and A-16. The remaining 22.2% (n = 2/9) were genotypically indistinguishable to patient B-8. Three interventions to decrease the risk of bacterial transmission were applied, with the final intervention including a switch of all keyboards and mice in NICU-A and B to disinfectable ones. Post-intervention prospective monitoring up to one year showed a decrease in blood culture positivity (P = 0.0019) and catheter-related blood stream infection rate (P = 0.016) before and after intervention.

Conclusion

ATP monitoring is an effective tool in identifying difficult to disinfect areas in NICUs. Non-medical devices may serve as reservoirs of pathogens causing nosocomial outbreaks, and HCWs' hands contribute to bacterial transmission in NICUs.

Introduction

Neonates in neonatal intensive care units (NICUs) are vulnerable to nosocomial infections, which in turn are associated with increased infection-related morbidities and mortalities. The incidences and outcomes of these infections are determined by the type of pathogen and its antimicrobial susceptibility patterns, accompanying underlying medical conditions or degree of immaturity of the neonate’s immune system, and the number and type of invasive procedures that the neonate is exposed to. Furthermore, frequent and continuous contact with healthcare workers (HCWs) can be a source or mode of transmission of hospital acquired infections (HAIs) (1). Therefore, infection control policies practiced by the unit are extremely important in reducing rates of HAIs.

In order to terminate an outbreak, extensive investigations are generally carried out to identify the source of outbreak by performing environmental cultures and screening the patients as well as HCWs. However, in a review of 276 NICU outbreaks, only 48.6% of the attempts have succeeded in identifying the source of outbreak (2). Because HAIs in the NICU are associated with poor outcome of the neonates as well as increased length of admission duration leading to additional healthcare costs (3), preventing these infections are a priority.

Adenosine triphosphate (ATP) bioluminescence testing is useful to assess environmental cleanliness in environments with very low microbial counts and provides rapid feedback allowing immediate changes in cleaning practices (4). No consensus exists on objectively measuring environmental cleanliness within hospitals, especially depending on the location, risk of patients acquiring hospital acquired infections, and procedures or activities going on in the area. Therefore, alternative methods have been developed for assessing environmental cleanliness, including the ATP bioluminescence assay (5, 6). The level of ATP measures the quantity of organic matter, however, because it cannot discriminate between viable bacteria nor distinguish potential pathogens, many studies have expressed doubts about the usefulness of bioluminescence for hygiene monitoring within healthcare settings (7). However, a review on ATP-bioluminescence in healthcare environments proposed a cutoff of 100 relative light unit (RLU) /100 cm2 in high risk environments (8).

To effectively prevent and control infectious disease outbreak in the NICU, a systematic approach and assessment of all possible sources, reservoirs, and modes of transmission of the pathogen must be examined. Therefore, the primary aim of this study was to assess the role of ATP bioluminescence level monitoring for effectively identifying possible sources or reservoirs of the outbreak pathogen and find modes of transmission during the two consecutive outbreaks caused by Enterococcus faecium and Staphylococcus capitis. The secondary aim was to evaluate the long-term sustainability of the infection control measures employed one year after the outbreak termination by investigating changes in the rate of hospital-acquired sepsis and hospital-acquired catheter-related blood stream infections (CRBSIs).

Methods

Study setting

Two consecutive outbreaks by different nosocomial bacteria—E. faecium and S. capitis—occurred during a span of 53 days at an NICU consisting of a total of 50 beds, of which 30 beds comprise subunit A and 20 beds comprise subunit B. The two subunits are located on opposite ends of the same floor with a hallway in between the two enclosed subunits which do not share on-duty nursing staff. However, they share the same attending physicians including neonatologists, residents, and interns. A nursery room for healthy newborns consisting of 20 bassinets are located in a separate area without any connections to the NICU. Sick or at-risk neonates are admitted directly after birth into either the NICU subunit A or B. Neonates are often transported between the nursery room and NICUs according to their medical needs, such as close monitoring or further evaluation and management (Fig. 1). A total of 75 resident nurses, 13 nursing assistants, 2 janitors, 4 residents, and 2 interns are assigned to NICU subunits A and B.

Fig. 1
figure 1

NICU patient placement map of Seoul St. Mary’s hospital. E. faecium outbreak occurred in neonates directly adjacent to the index patient, and then an additional sepsis case occurred in a patient located in the separated unit B. S. capitis outbreak occurred to neonates in unit A who were far apart from each other, and then the outbreak spread to unit B. M, mouse; NICU, neonatal intensive care unit; K, keyboard

The routine cleaning protocol of the NICU before the outbreaks was done by cleaning staffs twice a day, during the day and evening duty. The disinfection of the surfaces around the patients’ incubator and medical devices was done once a day using Biospot® (Hydrachem, West Sussex, England), where one Biospot® effervescent chloride tablet was dissolved in 1.5 L of clean water making an overall concentration of 200 ppm. All the surfaces of medical devices and floors around each incubator were soaked for 3 min and swiped off using disposable towels or naturally air dried.

Case definition

Sepsis was diagnosed in a patient with symptoms and/or signs of systemic infection plus E. faecium or S. capitis cultured from at least two peripheral blood cultures taken from different sites. Hospital-acquired infections were defined as positive cultures after 48 h of admission. Blood culture positivity rate was a percentage of the number of positive blood cultures divided by the total number of blood cultures tested in patients with symptoms and/or signs of systemic infection (with an onset of least 48 h after admission). Catheter-related blood stream infection (CRBSI) was diagnosed based on (1) a positive catheter tip culture or a positive blood culture drawn from the central venous catheter, (2) clinical symptoms and/or signs of systemic infection, and (3) a positive peripheral blood culture (9). The CRBSI rate was calculated by episodes per 1000 catheter days, and the p for trend was calculated. All patients with E. faecium and S. capitis sepsis had indwelling peripherally inserted central venous catheters that were unable to have blood drawn from.

Interventions to decrease the risk of bacterial transmission

The first intervention to decrease the risk of bacterial transmission consisted of increasing the frequency of environmental disinfection from once daily (every 24 h) to three times a day (every 8 h).

The second intervention was to change the method and type of disinfection from Biospot® (as described in the study setting) to ready-made wipes (single-step detergent and disinfectant) to reduce any possibilities of mixing impurities in the dissolution process: Clinell® (GAMA Healthcare Ltd., Hemel Hempstead, England) (1000 ppm) was used on non-invasive medical devices such as ultrasonic devices, stethoscopes, etc., whereas, Safecide® (Cosell, Hanam, South Korea) (200 ppm) was used on all other surfaces.

The third and final intervention measures were: (1) changing keyboards and mice to disinfectable ones and (2) education of the HCWs on hand hygiene.

Environmental surveillance

Environmental surface Adenosine triphosphate (ATP) bioluminescence levels were monitored using LUMITESTER PD-30 and LuciPac® Pen (R-Biopharm AG, Darmstadt, Germany). ATP monitoring consisted of checking ATP levels on environmental surfaces and medical devices at random visits by the infection control office during the day and evening shifts. The time of ATP measurement was randomly done during the day, prior to the disinfection. The tested area was 100cm2 including high-touched area around the patients’ incubator, medical devices, and also the surface of non-medical devices. Although the manufacturer defines a negative (clean) sample as a RLU level < 200 RLU/100 cm2 (10), in this study, all surfaces with ≥ 100 RLU/100 cm2 after disinfection were considered contaminated and thus re-cleaned, based on a review on ATP-bioluminescence in healthcare environments which proposed a cutoff of 100 RLU/100cm2 in high risk environments (8).

Environmental surface or medical device surface cultures were carried out on (1) areas with high ATP levels even after disinfection by protocol, (2) standardized environmental cultures from the patients’ surroundings (incubator handles, crash cart handles, stethoscopes, ventilator dials, infusion pump buttons, computer monitor buttons, keyboards, and mouse, (3) high-touch areas by HCW’s including keyboard and mice at the main station, with a total n = 49 environmental samples taken.

After the ATP measurements were made, the cleaning staffs and also the HCWs were given feedback on cleaning efficacy based on ATP level monitoring in order to improve environmental cleaning to decrease in the risk of environmental contamination consequently reducing the risk of pathogen transmission to bring forth a reduction in sepsis events.

Hand washing surveillance

Hand washing and hand sanitization monitoring was carried out via unannounced visits by validated and trained observers. New NICU staff members were given hand hygiene education, all workers were re-educated on hand hygiene, and feedbacks on hand hygiene monitoring were given after each monitoring. Rectal swab cultures from the patients with E. faecium sepsis were also performed.

Bacterial isolation, identification, and antibiotic susceptibility testing

Rectal swab cultures from the patients with E. faecium sepsis were also performed. All E. faecium and S. capitis isolated from patients with sepsis, healthcare workers’ hand cultures, and environmental cultures underwent species identification. Antibiotics susceptibilities were found using the automated microbiology system MicroScan Pos Breakpoint Combo Panel 44 (Siemens Healthcare Diagnostics Inc., West Sacramento, CA, USA). Pulsed-Field Gel Electrophoresis (PFGE) was carried out on the isolates (11), and SmaI PFGE patterns dendrogram was used to investigate the phylogenetic relatedness of the strains (12, 13).

Methods of environmental and hand cultures

Hand cultures of physicians, nurses, and nurses’ aides that were on duty were performed on day 36 and 42. A total 29 HCWs’ hand cultures were included. Methods for hand cultures were done as follows: tryptic soy broth was poured on the hands of the workers and collected into 50 mL falcon tubes. The tubes were then incubated in 35 ± 2 °C for 18–24 h. The bacterial colonies grown were subculture in blood agar plates. For environmental cultures, environmental surfaces were rubbed with and aseptic swab and streaked onto blood agar plates. The plates were also incubated in 35 ± 2 °C for 18–24 h.

Species identification and antibiotic susceptibility tests were done via MALDI-TOF VITEK® MS (bioMerieux, Marcy L’Etoile, France) and VITEK®-2 (bioMerieux, Marcy L’Etoile, France).

Statistics

The chi square test was used to calculate the significance of the change in sepsis rate before and after interventions. Interrupted time series analysis model was used to observe significance in variance between time periods before and after the intervention. All tests were two-tailed, and a P < 0.05 was considered statistically significant.

Ethical statement

The Institutional Review Board (IRB) of Seoul St. Mary's Hospital approved this study (IRB No. KC22RISI0690). Informed consent was waived due to retrospective study design.

Results

Description of the outbreaks

An E. faecium outbreak was first suspected when three preterm infants were diagnosed with E. faecium sepsis over a span of 12 days. The index case of the E. faecium outbreak was a preterm infant (A-8) born at gestational age 25 weeks and 4 days with a birthweight of 761 g. This infant was intubated and was diagnosed with necrotizing enterocolitis grade IIIB and therefore underwent double barrel ileostomy small bowel segmental resection one day prior to E. faecium sepsis, which occurred at 21 days of birth (Fig. 2). On day 26 after the E. faecium sepsis index case occurred, the S. capitis outbreak’s index case (A-16) was diagnosed with S. capitis sepsis. This preterm infant born at gestational age 29 weeks and 1 day with a birthweight of 1319 g had been diagnosed with respiratory distress syndrome (RDS) and patent ductus arteriosus (PDA), two weeks prior. This patient was diagnosed with S. capitis sepsis 21 days after birth. In total, four cases of E. faecium sepsis (A-8, A-7, A-9, B-8) and three cases of S. capitis sepsis (A-16, A-2, B-8) were diagnosed in 6 preterm infants over a span of 53 days (Fig. 2). The antibiotic susceptibility patterns of E. faecium and S. capitis cultured from the patients are on Additional file 1: A.

Fig. 2
figure 2

Timeline of the outbreak and intervention measures carried out. The outbreak was recognized on day 13, and intervention measures were applied after recognition. The first intervention consisted of increasing the frequency of environmental disinfection from once daily (every 24 h) to three times a day (every 8 h), the second intervention was to change the type of disinfectant from Biospot® to Clinell® and Safecide®. The final intervention consisted of changing keyboards and mice to disinfectable ones and education of the HCWs on hand hygiene based on the PFGE typing results. HCW health care worker; PFGE pulsed-field gel electrophoresis.

There were no sepsis episodes or CRBSIs caused by E. faecium or S. capitis within a 3-month period prior to the index cases. After investigations of the outbreaks and three interventions to reduce the risks of bacterial transmission (Fig. 2), no further cases of sepsis caused by E. faecium occurred during the one-year monitoring period after the final intervention and no more cases of S. capitis CRBSI occurred up to three months after the final intervention.

Description of infection control measures

The following outbreak response measures were carried out to identify the source of infection and prevent further transmission:

1) Alerting the hospital’s infection control office

The hospital’s infection control office was notified of a possible E. faecium outbreak on day 13 of the outbreak, after the identification of the third case of E. faecium sepsis. Together with the infection control office and NICU quality control team, outbreak management and three intervention measures were applied.

2) Investigation of possible sources and reservoirs in the environment

ATP levels were found to be especially high on keyboards of the computers designated to the beds of the patients with E. faecium sepsis, handles of the crash carts, and fluid infusion pump buttons (Table 1). Therefore, the first intervention of increasing the frequency of environmental disinfection was applied (Fig. 2). The disinfection areas included all the surfaces around patients’ surroundings, medical devices (e.g. ventilator) and also non-medical devices (e.g. desks, keyboards, mouse in the station, drug drawer, milk room desks, buttons of intercom etc.). After the increase in the frequency of environmental disinfection, follow-up random ATP levels on day 21 of the outbreak showed that the levels on the keyboards of bed A-8 (536 RLU/100 cm2) and A-9 (530 RLU/100 cm2), as well as the handle of crash cart by bed A-9 (785 RLU/100 cm2) remained high while the levels on other sites had decreased significantly (Table 1).

Table 1 Random environmental surface ATP bioluminescence levels during once daily versus every 8-h environmental disinfection protocols during the Enterococcus faecium outbreak in NICU subunit A (Intervention 1)

Because increasing the frequency of environmental disinfection was not enough to maintain a clean environment, the second intervention of changing the method and type of disinfectant was incorporated. The surface of areas such as keyboards, mice, handles of the crash carts, and ventilator buttons needed to be soaked for 3 min to be effectively disinfected with the current method of disinfection, however, this was considered to be difficult. Therefore, intervention 2 consisted of using ready-made wipes, Clinell® and Safecide® to wipe the surfaces without the need for soaking.

Even after the second intervention, follow up ATP levels at random times during the day remained very high on keyboard 1 of the main station (2076 RLU/100 cm2) and the keyboard of bed A-9 (4886 RLU/100 cm2). In addition, a high level of ATP was detected on the handle of the crash cart by bed A-2 (1307 RLU/100 cm2) (Table 2). In parallel to ATP monitoring, cultures were obtained from these three areas with high ATP levels even after disinfection by protocol. Three keyboard and mouse sets located in the main station in NICU-A where all medical staff have access to and frequently use, were also included.

Table 2 Random environmental surface ATP results during E. faecium/S. capitis outbreak in NICU-A after changing the disinfection method from Biospot® to Clinelle® and Safecide® (Intervention 2)

3) Investigation of transmission modes and identification of reservoirs

From the three high touch areas that maintained high levels of ATP after disinfection, E. faecalis was isolated from keyboard 1 of the main station, and S. capitis was isolated from keyboard of bed A-9 and crash cart handle by bed A-2.

Environment and HCW’s hand cultures showed that E. faecium was not isolated from hand cultures of HCWs, however, were isolated from environmental cultures (bed A-8, A-9 stethoscope, A-2 crash cart, and main station keyboard) and rectal cultures of the patients (2 out of 4: bed A-8, A-9). To find the genetic relatedness, all isolates underwent PFGE typing. E. faecium cultured from all four patients (A-7, A-8, A-9, B-8) and environmental cultures were found with a genotypically indistinguishable strain (Fig. 3a). Furthermore, E. faecium cultured from the main station’s keyboard 1 was also a genotypically indistinguishable strain (Fig. 3a, [1–13]). Because all medical staff had frequent usage of the main station keyboard 1, this was a possible reservoir for E. faecium.

Fig. 3
figure 3

Dendrogram of a E. faecium PFGE types from all four patients (A-7, A-8, A-9, B-8), environmental cultures, and keyboard 1 of the main station showing identical strains, and b S. capitis PFGE types from all three patients (A-2, A-16, B-8), HCW’s hand cultures, and environmental cultures. Two different S. capitis strains were found to be the cause of sepsis in the patients. Results showed that 77.8% of the S. capitis identified from HCWs were the same strain that caused the S. capitis sepsis in patients A-2 and A-16. The remaining 22.2% were the same strain that caused sepsis in patient B-8. The environments surrounding patients A-2 and A-16 were also found to be contaminated with the same S. capitis strain. HCW, health care worker; PFGE, Pulsed-Field Gel Electrophoresis

Two different S. capitis strains were found to be the cause of sepsis in the patients. Genotypically indistinguishable strains were isolated from patients A-2 and A-16, whereas a different strain was identified from patient B-8 (Fig. 3b). Furthermore, S. capitis was isolated from 31.0% (n = 9/29) of the HCWs’ hands. Of these, 100% (n = 9/9) had similar antibiotic sensitivity profiles with S. capitis isolated from the patients with sepsis and therefore underwent PFGE typing (Fig. 3b). Results showed that 77.8% (n = 7/9) were found to be colonized with a genotypically indistinguishable strain causing S. capitis sepsis in patients A-2 and A-16. The remaining 22.2% (n = 2/9) were found with a genotypically indistinguishable strain that caused sepsis in patient B-8. The environments surrounding patients A-2 and A-16 were also found to be contaminated with the same S. capitis strain. The S. capitis isolated from keyboard of bed A-9 and crash cart handle by bed A-2A with high ATP levels after disinfection were a different strain. A common environmental reservoir was not found for S. capitis other than HCWs’ hands and environments immediately surrounding patients A-2 and A-16 (Fig. 3b).

With the possible reservoir of E. faecium identified as the main station’s keyboard 1, and mode of transmission for S. capitis as HCW’s hands, the 3rd intervention was incorporated. After the main station’s keyboard 1 and its mouse set were switched to a disinfectable keyboard and mouse, ATP levels were checked before and after disinfection to assess the effectiveness of the disinfection procedures. Compared to a conventional keyboard and mouse set located at the main station, keyboard 2 and mouse 2, the disinfectable keyboard and mouse set maintained low ATP levels prior to disinfection and were effectively decontaminated (Table 3). Based on these results, all keyboard and mouse sets in both NICU-A and B were switched to medical ones.

Table 3 Comparison of random environmental surface ATP results immediately before and 1 h after disinfection in disinfectable keyboard and mouse versus conventional keyboard and mouse (Intervention 3)

Assessing long-term effects of the infection control measures

Prospective surveillance of hospital acquired sepsis and CRBSI rates were monitored up to 12 months after the third (final) intervention (Fig. 4). During the one-year period prior to the incorporation of the final infection control measures, blood culture positivity rate was 4.2% (n = 71/1698) which fell to 1.6% (n = 26/1590) during the 1st year after the final intervention (P = 0.0019). Furthermore, the CRBSI rate was 3.7 episodes per 1000 catheter days during the one-year prior to the interventions, and fell to 2.0 episodes per 1000 catheter days during the 1st year after the final intervention (P = 0.0592) (Fig. 4) (Monthly figures of blood culture positivity rate and CRBSI rate are on Additional file 1: B, C). During the one-year monitoring period after the final intervention, two cases of CRBSI caused by S. capitis occurred at 4 and 11 months after the final intervention.

Fig. 4
figure 4

Interrupted time series analysis of monthly cases. a During the one-year period prior to the incorporation of the final infection control measures, blood culture positivity rate was 4.2% which fell to 1.6% during the 1st year after the final intervention (P = 0.0019). b The CRBSI rate was 3.7 episodes per 1000 catheter days during the one-year prior which fell to 2.0 episodes per 1000 catheter days during the 1st year after the final intervention (P = 0.0592). CRBSI, catheter-related blood stream infection

Discussion

Successful control of infectious disease outbreak in intensive care settings are important for minimizing its damaging effects. In this study, through ATP monitoring, high-touch areas where disinfection protocols failed to disinfect surfaces were identified and cultures were performed from these areas. By performing cultures on these surfaces, a non-medical computer device, keyboard 1, located at the main station of NICU-A was identified as one possible reservoir of E. faecium, which failed to decontaminate after intervention 1 and 2. Although areas of environmental surface contamination were identified for S. capitis, a common reservoir was not found. However, HCW’s hands were found to be colonized with a genotypically indistinguishable S. capitis strain that caused sepsis in the patients. Interventions including the disinfection of contaminated surfaces and reservoirs, as well as education and feedback on the importance of hand hygiene procedures based on the hand culture results of HCWs were effective in sustaining a decreased nosocomial infection rate in the NICU.

Successful outbreak management requires sterilization of not only the source or reservoirs but recognizing environmental factors, such as contaminated areas that may foster an outbreak (14, 15). However, finding these contaminated areas are difficult because bacterial contamination is not visible. Monitoring ATP bioluminescence levels have been shown to be a useful tool for identifying surfaces in hospitals and assessing the efficiency of cleaning procedures (4, 16, 17). In this study, through random ATP level testing, areas that were difficult to decontaminate or re-contaminate easily were discovered. In these areas, universal environmental disinfection procedures along with targeted disinfection of these easily re-contaminated areas were possible. Regardless of frequent disinfection and utilizing effective disinfectants, keyboard and mouse surfaces were found to be areas that were not only difficult to decontaminate, but also areas that were easily re-contaminated, serving as a source or reservoir of bacteria. Other studies have also shown that computer keyboards are contaminated with bacteria and can serve as a vehicle for transmission of pathogens to patients (18,19,20). These studies warrant that computers including keyboards should be disinfected frequently and hand hygiene procedures should be obeyed by the hospital staff before and after coming into contact with patients.

On the contrary, a systematic review of 75 studies involving 2804 computer devices reported that the overall proportion of contamination with skin commensals and potential pathogens was reported to range from 24 to 100%. However, this study concluded that the impact on transmission and nosocomial infection was unclear and warranted further studies to draw firm conclusions (21). Another study reported that whole genome sequencing showed patients with nosocomial infections had a different genotype than of those cultured from the keyboard. Therefore, although keyboard were a reservoir of multidrug-resistant organisms, they appeared unlikely to contribute to nosocomial infections (22). Our study contradicts this study, because through PFGE typing, we found that E. faecium isolated from patients with sepsis were genotypically the same strain as those isolated from a keyboard located in a distant area from patients. This shows that computer devices such as keyboards that are located in a distant area from patients can act as reservoirs, further highlighting the importance of environmental disinfection of high-touch areas by HCWs within all areas of the unit in preventing outbreaks by nosocomial pathogens. Furthermore, although we were unable to find E. faecium on the hands of employees, the hands must have also played a role in the transfer from keyboard to the patients.

Although many efforts were made to disinfect high-touch areas, the conventional keyboard and mouse sets were found to be difficult to decontaminate and were also easily re-contaminated. Therefore, all keyboards in the NICU were switched to disinfectable keyboards and mice, making disinfection procedures easier due to the absence of crevices and hidden surfaces between the keys. Furthermore, due to the smooth and regular surfaces of the disinfectable keyboards and mice, as well as surface material that allows lower rates of contamination, the long-term effects of the switch from conventional keyboards to disinfectable keyboards throughout the NICU contributed to lowering overall rates of CRBSIs up to one year after the final intervention.

The value of screening HCWs during an investigation of a nosocomial outbreak is yet unclear. A systematic review by Ulrich et al. reported that HCWs are rarely identified as the cause of outbreaks, and screening HCWs did not give any additional information (23, 24). However, in another study that reported an outbreak of S. capitis inside a NICU, S. capitis was cultured from HCW’s hand, and although this study did not perform genotyping, the study suggested that HCWs could be involved in inter-patient transmission of S. capitis (25). Through genotyping, our study showed that HCWs carried genotypically indistinguishable S. capitis strains that caused sepsis in the patients, and therefore contributed to the transmission of S capitis.

Limitations of this study are that disinfectants used in this study and/or the timing of testing may have influenced ATP results. Secondly, ATP level monitoring was carried out on high-touch surfaces and not all hospital surfaces were included, providing possible bias in showing all contaminated areas. Also, not all HCW’s hand cultures were performed due to the nature of the random visits, which were deemed important to investigate colonization of the HCWs hands during duty. Finally, we were unable to include all sterile site infections or acquisition including carriage in this study, which limits representation of all transmission events.

Conclusions

To conclude, this study showed that ATP monitoring was an effective tool in identifying areas that are difficult to disinfect. By culturing these areas, this study showed that non-medical devices such as keyboards can act as a reservoir of nosocomial pathogens. Furthermore, this study showed that colonization of potential pathogens in HCWs’ hands contributed to the transmission of nosocomial pathogens in NICUs. CRBSI rates before and after the interventions, which were disinfection of the reservoirs, adjustments to the disinfection policy and education on hand hygiene procedures, showed that the sustainability of the interventions was successful.

Availability of data and materials

The datasets used and/or analyzed during the current study are partially available from the corresponding author on reasonable request.

Abbreviations

ATP:

Adenosine triphosphate

NICU:

Neonatal intensive care unit

PFGE:

Pulsed-field gel electrophoresis

RLU:

Relative light units

CRBSI:

Catheter-related blood stream infection

HCW:

Healthcare workers

HAI:

Hospital acquired infections

IRB:

Institutional Review Board

RDS:

Respiratory distress syndrome

PDA:

Patent ductus arteriosus

VRE:

Vancomycin-resistant Enterococci

References

  1. Johnson J, Quach C. Outbreaks in the neonatal ICU: a review of the literature. Curr Opin Infection Dis. 2017;30(4):395–403.

    Article  Google Scholar 

  2. Gastmeier P, Loui A, Stamm-Balderjahn S, Hansen S, Zuschneid I, Sohr D, et al. Outbreaks in neonatal intensive care units—they are not like others. Am J Infection Control. 2007;35(3):172–6.

    Article  Google Scholar 

  3. Curtis C, Shetty N. Recent trends and prevention of infection in the neonatal intensive care unit. Curr Opin Infect Dis. 2008;21(4):350–6.

    Article  PubMed  Google Scholar 

  4. Sanna T, Dallolio L, Raggi A, Mazzetti M, Lorusso G, Zanni A, et al. ATP bioluminescence assay for evaluating cleaning practices in operating theatres: applicability and limitations. BMC Infect Dis. 2018;18(1):583.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Dancer SJ. Controlling hospital-acquired infection: focus on the role of the environment and new technologies for decontamination. Clin Microbiol Rev. 2014;27(4):665–90.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Shama G, Malik DJ. The uses and abuses of rapid bioluminescence-based ATP assays. Int J Hyg Environ Health. 2013;216(2):115–25.

    Article  CAS  PubMed  Google Scholar 

  7. Whiteley GS, Derry C, Glasbey T, Fahey P. The perennial problem of variability in adenosine triphosphate (ATP) tests for hygiene monitoring within healthcare settings. InfectION Control Hosp Epidemiol. 2015;36(6):658–63.

    Article  Google Scholar 

  8. Mulvey D, Redding P, Robertson C, Woodall C, Kingsmore P, Bedwell D, et al. Finding a benchmark for monitoring hospital cleanliness. J Hosp InfectION. 2011;77(1):25–30.

    Article  CAS  Google Scholar 

  9. Fletcher S. Catheter-related bloodstream infection. Contin Educ Anaesth Crit Care Pain. 2005;5(2):49–51.

    Article  Google Scholar 

  10. Lumitester PD-20/PD-30 and LuciPac® Pen - Bio-Strategy. https://www.bio-strategy.com/site/bio-strategy-nz/files/Supplier_Subs/RBIO_Lumitester_Examples_0319.pdf. Accessed 14 July 14 2022. [Internet].

  11. Murchan S, Kaufmann ME, Deplano A, de Ryck R, Struelens M, Zinn CE, et al. Harmonization of pulsed-field gel electrophoresis protocols for epidemiological typing of strains of methicillin-resistant Staphylococcus aureus: a single approach developed by consensus in 10 European laboratories and its application for tracing the spread of related strains. J Clin Microbiol. 2003;41(4):1574–85.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  12. Garcia-Vallve S, Palau J, Romeu A. Horizontal gene transfer in glycosyl hydrolases inferred from codon usage in Escherichia coli and Bacillus subtilis. Mol Biol Evol. 1999;16(9):1125–34.

    Article  CAS  PubMed  Google Scholar 

  13. DendroUPGAM: A dendrogram construction utilitys. Created at March 2002. http://genomes.urv.cat/UPGMA/. Accessed 1 July 2021.

  14. Gastmeier P, Vonberg R-P. Outbreaks of nosocomial infections: lessons learned and perspectives. Current Opin Infect Dis. 2008;21(4):357–61.

    Article  Google Scholar 

  15. Yu IT, Xie ZH, Tsoi KK, Chiu YL, Lok SW, Tang XP, et al. Why did outbreaks of severe acute respiratory syndrome occur in some hospital wards but not in others? Clin Infect Dis Off Publ Infect Dis Soc Am. 2007;44(8):1017–25.

    Article  Google Scholar 

  16. Moore G, Smyth D, Singleton J, Wilson P. The use of adenosine triphosphate bioluminescence to assess the efficacy of a modified cleaning program implemented within an intensive care setting. Am J Infection Control. 2010;38(8):617–22.

    Article  Google Scholar 

  17. van Arkel A, Willemsen I, Kilsdonk-Bode L, Vlamings-Wagenaars S, van Oudheusden A, Waegemaeker P, et al. ATP measurement as an objective method to measure environmental contamination in 9 hospitals in the Dutch/Belgian border area. Antimicrob Resist Infection Control. 2020;9(1):77.

    Article  Google Scholar 

  18. Schultz M, Gill J, Zubairi S, Huber R, Gordin F. Bacterial contamination of computer keyboards in a teaching hospital. Infection Control Hosp Epidemiol. 2003;24(4):302–3.

    Article  Google Scholar 

  19. Bures S, Fishbain JT, Uyehara CFT, Parker JM, Berg BW. Computer keyboards and faucet handles as reservoirs of nosocomial pathogens in the intensive care unit. Am J Infection Control. 2000;28(6):465–71.

    Article  CAS  Google Scholar 

  20. Doğan M, Feyzioğlu B, Ozdemir M, Baysal B. Investigation of microbial colonization of computer keyboards used inside and outside hospital environments. Mikrobiyol Bul. 2008;42(2):331–6.

    PubMed  Google Scholar 

  21. Ide N, Frogner BK, LeRouge CM, Vigil P, Thompson M. What’s on your keyboard? A systematic review of the contamination of peripheral computer devices in healthcare settings. BMJ Open. 2019;9(3): e026437.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Smibert OC, Aung AK, Woolnough E, Carter GP, Schultz MB, Howden BP, et al. Mobile phones and computer keyboards: unlikely reservoirs of multidrug-resistant organisms in the tertiary intensive care unit. J Hosp Infection. 2018;99(3):295–8.

    Article  CAS  Google Scholar 

  23. Vonberg RP, Stamm-Balderjahn S, Hansen S, Zuschneid I, Ruden H, Behnke M, et al. How often do asymptomatic healthcare workers cause methicillin-resistant Staphylococcus aureus outbreaks? A systematic evaluation. Infection Control Hosp Epidemiol. 2006;27(10):1123–7.

    Article  Google Scholar 

  24. Ulrich N, Gastmeier P, Vonberg R-P. Effectiveness of healthcare worker screening in hospital outbreaks with gram-negative pathogens: a systematic review. Antimicrob Resist Infection Control. 2018;7(1):36.

    Article  Google Scholar 

  25. Butin M, Dumont Y, Monteix A, Raphard A, Roques C, Martins Simoes P, et al. Sources and reservoirs of Staphylococcus capitis NRCS-A inside a NICU. Antimicrob Resist Infection Control. 2019;8(1):157.

    Article  Google Scholar 

Download references

Acknowledgements

We would like to thank the Infection control office of Seoul St. Mary’s Hospital.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

YJK- Study design, data acquisition, data analysis, data interpretation, manuscript writing. MYH- Data acquisition, data analysis, final approval of submitted version. HMK- Study conception, design, data analysis, data interpretation, critical revision of draft, final approval of submitted version. SKY-Data analysis, data interpretation, final approval of submitted version. YAY-Data analysis, data interpretation, final approval of submitted version. DGL-Data analysis, data interpretation, final approval of submitted version. JHK-Data interpretation, final approval of submitted version. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Hyun Mi Kang.

Ethics declarations

Ethics approval and consent to participate

This investigation was approved by the Institutional Review Board (IRB) of Seoul St. Mary's Hospital (IRB No. KC22RISI0690). Informed consent was waived.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

. Supplementary Material A. Antibiotic susceptibility patterns of E. faecium and S. capitis cultured from the patients’ blood. Supplementary Material B. Monthly data on Blood culture positivity rate. Supplementary Material C. Monthly data on Episodes per 1,000 catheter days for all pathogens.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, Y.J., Hong, M.Y., Kang, H.M. et al. Using adenosine triphosphate bioluminescence level monitoring to identify bacterial reservoirs during two consecutive Enterococcus faecium and Staphylococcus capitis nosocomial infection outbreaks at a neonatal intensive care unit. Antimicrob Resist Infect Control 12, 68 (2023). https://doi.org/10.1186/s13756-023-01273-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13756-023-01273-5

Keywords